Search results for "Adaptive optics"

showing 10 items of 37 documents

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct

Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration

2011

Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…

AdultDepth of focusCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityArtificial Lens Implant MigrationCohort StudiesYoung AdultAberrometryPsychophysicsmedicineHumansContrast (vision)Adaptive opticsmedia_commonMathematicsLenses IntraocularDepth PerceptionMonocularAberrometryModels Theoreticalequipment and supplieseye diseasesSensory SystemsOphthalmologySpherical aberrationTilt (optics)OptometrySurgerysense organsmedicine.symptomJournal of Cataract and Refractive Surgery
researchProduct

Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.

2014

Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …

AdultDepth of focusPhakic Intraocular LensesVisual acuityCorneal Wavefront Aberrationgenetic structuresVisual AcuityDiagnostic Techniques OphthalmologicalPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineHumansComputer SimulationAdaptive opticsDioptreMathematicsWavefrontDepth PerceptionPupilPresbyopiaPresbyopiamedicine.diseaseeye diseasesSensory SystemsOphthalmologySpherical aberrationOptometrySurgerysense organsmedicine.symptomJournal of cataract and refractive surgery
researchProduct

Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator

2013

PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …

AdultMalePoint spread functionOptics and PhotonicsDepth of focusmedicine.medical_specialtymedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis Designlaw.inventionContrast SensitivityYoung AdultOpticslawOptical transfer functionOphthalmologymedicineHumansComputer SimulationAdaptive opticsLenses IntraocularPhysicsDepth PerceptionMonocularbusiness.industryAccommodation OcularStrehl ratioLens (optics)OphthalmologyFemalebusinessOptometryOptometry and Vision Science
researchProduct

Accommodation Responds to Optical Vergence and Not Defocus Blur Alone.

2017

Purpose To determine whether changes in wavefront spherical curvature (optical vergence) are a directional cue for accommodation. Methods Nine subjects participated in this experiment. The accommodation response to a monochromatic target was measured continuously with a custom-made adaptive optics system while astigmatism and higher-order aberrations were corrected in real time. There were two experimental open-loop conditions: vergence-driven condition, where the deformable mirror provided sinusoidal changes in defocus at the retina between -1 and +1 diopters (D) at 0.2 Hz; and blur-driven condition, in which the level of defocus at the retina was always 0 D, but a sinusoidal defocus blur …

AdultMalegenetic structuresVisual AcuityVergenceAstigmatismRefraction Ocular050105 experimental psychologyDeformable mirror03 medical and health sciences0302 clinical medicineOpticsmedicineHumans0501 psychology and cognitive sciencesAdaptive opticsDioptreMathematicsWavefrontbusiness.industry05 social sciencesAccommodation OcularAstigmatismConvergence Ocularmedicine.diseaseeye diseases030221 ophthalmology & optometryFemalesense organsMonochromatic colorCuesbusinessAccommodationPhotic StimulationInvestigative ophthalmologyvisual science
researchProduct

Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator

2013

To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…

AdultMicrosurgeryOptics and PhotonicsPhakic Intraocular LensesVisual acuityAdolescentgenetic structuresComputer sciencemedia_common.quotation_subjectVisual AcuityPhakic intraocular lensPupilYoung AdultLens Implantation IntraocularOptical transfer functionmedicineHumansContrast (vision)Prospective StudiesAdaptive opticsVision OcularSimulationDioptremedia_commonAberrometryStrehl ratioeye diseasesRefractive Surgical ProceduresOphthalmologysense organsmedicine.symptomAmerican Journal of Ophthalmology
researchProduct

New Objective Refraction Metric Based on Sphere Fitting to the Wavefront

2017

Purpose. To develop an objective refraction formula based on the ocular wavefront error (WFE) expressed in terms of Zernike coefficients and pupil radius, which would be an accurate predictor of subjective spherical equivalent (SE) for different pupil sizes.Methods. A sphere is fitted to the ocular wavefront at the center and at a variable distance,t. The optimal fitting distance,topt, is obtained empirically from a dataset of 308 eyes as a function of objective refraction pupil radius,r0, and used to define the formula of a new wavefront refraction metric (MTR). The metric is tested in another, independent dataset of 200 eyes.Results. For pupil radiir0≤2 mm, the new metric predicts the equ…

Article SubjectMean squared errorZernike polynomials01 natural sciences010309 optics03 medical and health sciencessymbols.namesake0302 clinical medicinelcsh:Ophthalmology0103 physical sciencesMedicineComputer visionAdaptive opticsWavefrontbusiness.industryMathematical analysisFunction (mathematics)RadiusRefractionOphthalmologylcsh:RE1-994Metric (mathematics)030221 ophthalmology & optometrysymbolsArtificial intelligencebusinessResearch ArticleJournal of Ophthalmology
researchProduct

The 2-μm spectroscopy of Huygens probe landing site on Titan with Very Large Telescope/Nasmyth Adaptive Optics System Near-Infrared Imager and Spectr…

2007

[1] Several ground-based telescopes followed the event of the Huygens probe descent through Titan's atmosphere (14 January 2005). We used the Nasmyth Adaptive Optics System Near-Infrared Imager and Spectrograph (NACO) adaptive optics system at the UT-4 of the Very Large Telescope in Chile to perform both spectroscopic and imaging measurements of Titan. We present here a selected sample of the spectra we acquired on 16 January 2005 in the K band between 2.03 and 2.40 μm. Our spectra include the Huygens landing site and surrounding dark and bright areas. We apply a radiative transfer code using new methane absorption coefficients calculated in the 2-μm region. The analysis of the data yields …

Atmospheric Science010504 meteorology & atmospheric sciencesSoil ScienceAquatic ScienceOceanography01 natural sciencesSpectral lineadaptive opticssymbols.namesakeOpticsGeochemistry and Petrology0103 physical sciencesEarth and Planetary Sciences (miscellaneous)Radiative transfersurfaceSpectroscopyAdaptive optics010303 astronomy & astrophysicsSpectrograph0105 earth and related environmental sciencesEarth-Surface ProcessesWater Science and TechnologyPhysicsVery Large TelescopeEcology[SDU.ASTR]Sciences of the Universe [physics]/Astrophysics [astro-ph]business.industryNear-infrared spectroscopyPaleontologyForestryhaze[SDU.ASTR.IM]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Instrumentation and Methods for Astrophysic [astro-ph.IM]Geophysics13. Climate actionSpace and Planetary Scienceradiative transferHuygenssymbolsbusinessTitan (rocket family)Titan
researchProduct

Color and Flow Based Superpixels for 3D Geometry Respecting Meshing

2014

We present an adaptive weight based superpixel segmentation method for the goal of creating mesh representation that respects the 3D scene structure. We propose a new fusion framework which employs both dense optical flow and color images to compute the probability of boundaries. The main contribution of this work is that we introduce a new color and optical flow pixel-wise weighting model that takes into account the non-linear error distribution of the depth estimation from optical flow. Experiments show that our method is better than the other state-of-art methods in terms of smaller error in the final produced mesh.

Color histogramComputer sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONOptical flow010103 numerical & computational mathematics02 engineering and technologyImage segmentation01 natural sciencesWeightingDistribution (mathematics)[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV]Flow (mathematics)Computer Science::Computer Vision and Pattern Recognition[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV][ INFO.INFO-TI ] Computer Science [cs]/Image Processing0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processingComputer visionArtificial intelligence0101 mathematicsbusinessRepresentation (mathematics)Adaptive opticsComputingMilieux_MISCELLANEOUS
researchProduct